ちゃんとした NC-UV0609MAX-Ⅱ Scraper replacement​ keeps the industrial printheads clean during maintenance cycles. The NC-UV0609MAX-II prints 600×900 mm with 0–180 mm height, uses Epson 13200-U1 white, 13200-U1HD color and 11600-U1 varnish, runs CMYK+LC+LM+LK+LIK+W+V at 720×600/900/1200 dpi, FlexiPRINT ミニサーバー 22, 470W, AC220/110V, negative-pressure eco UV ink, 25–28℃ / 35–65%相対湿度. The ink station includes a wiper motor, cap top, peristaltic pump and waste cartridge; the manual troubleshoots color mixing by checking whether the scraper scrapes the nozzle mirror normally during auto cleaning. Replacing a worn scraper restores even wiping and prevents banding.

準備

プリンターの電源を切り、プラグを抜きます; 接地を確認する. ニトリル手袋を着用する. Open the cover and move the carriage to the maintenance position through the panel, driver or FlexiPRINT. Prepare a new genuine Nocai scraper/wiper, 糸くずの出ないワイプ, Nocai UV洗浄液, tweezers and a small driver. Photograph the wiper holder, scraper angle and cable before removal.

Removing the old scraper

Release the wiper holder screw or clip and slide out the old scraper. Inspect the rubber edge for hardening, ひび割れ, ink cake or uneven wear. The NC-UV0609MAX-II maintenance workflow supports manual scraping, auto cleaning and nozzle test; a damaged blade that cannot wipe the nozzle mirror causes residual ink and streaking. Dispose of the old blade safely because UV ink residue is sticky.

Installing the new scraper

Fit the OEM scraper in the original orientation and align its edge parallel to the nozzle plates. Tighten the holder lightly per the Nocai manual—avoid excess pressure that bends the blade or touches nozzles. Clean the cap top and surrounding ink station with UV cleaning solution. Confirm the wiper motor can drive the scraper smoothly across all heads without obstruction.

Auto clean and nozzle test

電源を入れる, run Auto Cleaning in the driver or FlexiPRINT; the system executes scraping, ink washing and capping as configured. Print a nozzle test on transparent media; all CMYK+W+V channels should fire evenly. If gaps remain, clean again and retest. When output is streak-free, the NC-UV0609MAX-II Scraper replacement​ is complete and the printer is ready for production.

Post-replacement care

Wipe the scraper edge daily with UV cleaning solution, service the cap station and encoder strip per the manual, Nocaiオリジナルインクのみを使用してください, wiper and spare parts. Non-Nocai ink voids after-sales support. Keep 25–28°C / 35–65% RH for stable wiper performance.