NC-UV0609MAX-II Peristaltic pump replacement

ちゃんとした NC-UV0609MAX-Ⅱ Peristaltic pump replacement​ restores strong cleaning suction on this 600×900 mm industrial UV printer. NC-UV0609MAX-II は 0 ~ 180 mm の高さを印刷します, Epson 13200-U1 ホワイトを使用, 13200-U1HD カラーと 11600-U1 ワニス, CMYK+LC+LM+LK+LIK+W+V を 720×600/900/1200 dpi で実行, FlexiPRINT ミニサーバー 22, 470W, AC220/110V, 負圧エコUVインク, 25–28℃ / 35–65%相対湿度. Its ink station integrates a wiper motor, キャップトップ, ペリスタルティックポンプと廃液カートリッジ. A weak pump leaves residual ink, causes dry nozzles and poor auto cleaning. Fitting an OEM Nocai pump returns reliable suction.

準備

電源を切る, プラグを抜いてアースを確認してください. ニトリル手袋を着用する. Through the panel, ドライバーまたはFlexiPRINT, park the carriage at the maintenance position. Prepare an OEM Nocai peristaltic pump, matching silicone tubes, small drivers, ピンセット, ワイプ, UV cleaning solution and bracket photos. Relieve negative pressure, then label every inlet and outlet tube. Do not kink tubes or touch the printheads during setup.

Remove the old pump

Disconnect the pump cables from the board and label polarity. Loosen tube clamps, remove the inlet from the cap/wash side and the outlet to the waste bottle, then unbolt the pump head or motor bracket. Inspect rollers, silicone tube hardness, cracks and ink buildup. Replace both the pump assembly and worn tubing when suction drops, pulsates or leaks during auto cleaning.

Install the new pump

Mount the OEM Nocai pump in the original orientation and tighten the bracket evenly. Fit specified silicone tubes without twists, secure clamps, and align rotation direction per the NC-UV0609MAX-II manual. Reconnect the power cable, route wires away from the X-axis belt, carriage path and UV lamp. Confirm the inlet serves the cap station and the outlet reaches the waste cartridge or bottle.

Prime and cleaning test

電源を入れる, enter standby maintenance, run manual pumping until cleaning fluid and ink flow to the waste path, then run Auto Cleaning. The system executes scraping, インクの洗浄とキャッピング. 透明なメディアにノズル テストを印刷する; すべての CMYK+W+V チャネルが均等に実行される必要があります. If suction stays weak, recheck tubes, direction and clamps. Stable suction completes the NC-UV0609MAX-II Peristaltic pump replacement.

交換後のケア

Inspect tubes weekly for flattening, replace silicone lines per manual, and empty the waste cartridge regularly. Wipe the cap top, wiper and encoder strip, keep 25–28°C / 35–65%相対湿度, and use only Nocai eco UV ink with original pump parts. Non-Nocai consumables void after-sales support.