ちゃんとした NC-UVA3MAX Ink Pad Replacement keeps the waste-ink system clean on this desktop UV printer. The NC-UVA3MAX uses one Epson I3200-U1HD head, prints 297×420 mm with 0–90 mm media height, runs CMYK+W+V at up to 1200 dpi, 今後のRIP, 140W, AC220/110V, エコUVインク, 25–28℃ / 35–65%相対湿度, 64 kg . 自動クリーニング中, scraping and pumping, excess ink collects near the cap station and waste path. A saturated or hardened pad causes overflow, chassis contamination, odor and nozzle problems. Swapping in a genuine Nocai pad restores safe waste management.
準備
Power off and unplug the printer before any maintenance . Wear nitrile gloves and place a tray under the cap station. Prepare a new OEM Nocai ink pad, 糸くずの出ないワイプ, UV認定洗浄液, ピンセット, a small screwdriver and absorbent paper. Move the carriage to the maintenance position from the panel. キャップステーションのカバーの写真を撮る, pad tray and waste tube before removal so nothing is reassembled wrongly.
Remove the old pad
Open the cap-station cover and locate the waste pad beside or under the capping area. Lift the old pad gently with tweezers—do not squeeze it, because trapped UV ink may leak. If your unit routes waste to a bottle instead of a sponge pad, disconnect the tube and empty or replace the bottle. Seal all waste in a plastic bag for proper chemical disposal.
Clean and install the new pad
Wipe the tray with cleaning-solution-moistened wipes to remove dried ink and debris. Check the waste tube for blockage and flush it if needed, then let the tray dry. Fit the OEM pad flat across the whole tray bottom without folds or gaps. Reinstall the cap-station cover, reconnect the waste tube and make sure the tube has no kinks near the carriage path.
Test and verify
Power on and enter the maintenance menu. Run manual pumping, then Auto Cleaning so the system scraps, washes and caps the head. Watch the waste path for leaks. 透明なメディアにノズル テストを印刷する; all CMYK+W+V channels should fire evenly with no streaks. No overflow means the NC-UVA3MAX Ink Pad Replacement is complete.
交換後のケア
最初の 1 か月間は毎週パッドまたはボトルを検査してください, それから毎月. 部屋を25~28℃に保つ / 35–65%相対湿度, clean the cap station regularly, and use only Nocai original pads and eco UV ink to protect print quality and after-sales support.