NC-UV0406-VI 光栅条更换

恰当的 NC-UV0406-VI grating strip replacement​ restores accurate X-axis positioning for the dual Epson I1600-U1 printheads. NC-UV0406-VI是一款400×600毫米平板A2桌面UV打印机, 0–180 毫米高度, CMYK+W 或 CMYK+W+V 最多 1200 分辨率, FlexiPRINT MiniServer 22 Nocai Edition, 143瓦, 交流220/110V, 和生态UV墨水; 25–28°C 时效果最佳 / 35–65% 相对湿度 . The grating strip acts as the carriage ruler; a dirty, 划伤的, loose, or broken strip causes ghosting, wrong margins, homing faults, or carriage crashes. Replacing it with a matched Nocai strip returns stable positioning.

准备

关闭打印机电源并拔掉电源插头. 戴防静电手套. Move the carriage to the middle of the beam so the strip is relaxed. Open the transparent cover and loosen the upper/side screws as instructed in the Nocai manual. Prepare lint-free wipes, ≥99%异丙醇, a Phillips driver, 镊子, and a new OEM grating strip specified for NC-UV0406-VI. Photograph the strip ends, card brackets, reader position, and X-axis limit switch before removal.

拆除旧条带

Do not touch the engraved scale with fingers. Loosen the strip-card screws or end brackets gently. Slide the old strip out of the reader sensor slot first, then release both end fixtures. Inspect for ink mist, 划痕, grease, or slack tension. If only dust causes reading errors, clean with alcohol and retest; replace only when damage remains. Avoid pulling the reader sensor or X-axis limit switch during removal.

安装新条带

Fit one fixed end of the new strip, then route it straight through the reader slot without twisting. Keep the strip centered in the sensor gap, apply even tension per manual, and secure the spring or card bracket at the other end. The strip should be parallel to the carriage beam and not contact the printheads, cables, or UV lamp area. Recheck that numbers or reference marks face the correct direction if the OEM part is directional.

Homing and Accuracy Test

Power on and run the homing sequence; the carriage should move to the origin and return correct X-axis readings. In FlexiPRINT, print an alignment chart and a small grid pattern; measure printed size against the design size. If margins drift or ghosting remains, recheck strip centering, tension, and reader cleanliness. When X-axis readings are stable and output size matches, the NC-UV0406-VI grating strip replacement​ is complete and the printer is ready for production.