NC-UVDTF60 Nozzle plate replacement
2026-08-23 60 조회수
적절한 NC-UVDTF60 Nozzle plate replacement becomes necessary when the printhead shows persistent nozzle clogging, 물리적 손상, or degraded print quality that cleaning cycles cannot resolve. The nozzle plate is the final ink ejection surface; a worn, scratched, or clogged plate causes missing nozzles, ink deflection, and poor image quality. Replacing it restores jetting performance and extends printhead life. Because this procedure involves delicate printhead components, always power off the printer and follow the steps carefully. Use only genuine NOCAI parts to maintain warranty coverage.
준비
프린터 전원을 끄고 전원 케이블을 분리하세요.. Wear antistatic gloves and a wrist strap. 깨끗하게 준비하세요, static-free workspace with good lighting. 당신은 필요합니다: a new genuine NOCAI nozzle plate matched to your printhead model (i1600 or i3200), 보푸라기가 없는 물티슈, 이소프로필 알코올 (≥99%), 정밀 드라이버 세트, 족집게, and the NC-UVDTF60-PLUS user manual.
기존 노즐 플레이트 제거
전면 덮개를 열고 캐리지를 유지 관리 위치로 이동합니다.. Locate the printhead and carefully unscrew the retaining screws holding the old nozzle plate. 프린트 헤드 본체에서 플레이트를 조심스럽게 들어올립니다.. 노출된 잉크 채널이나 노즐 표면을 만지지 마십시오.. 오래된 접시를 올바르게 폐기하십시오..
장착 표면 청소
이소프로필 알코올을 적신 보풀 없는 천을 사용하여 프린트 헤드의 장착 표면을 청소합니다.. 건조된 잉크 잔여물과 부스러기를 모두 제거합니다.. 2~3분 동안 표면이 완전히 건조되도록 놔두세요.. 긁힌 자국이나 거친 부분이 있는지 검사하세요.; 존재하는 경우, 계속하기 전에 NOCAI 지원팀에 문의하세요..
새 노즐 플레이트 설치
새 노즐판을 프린트 헤드의 정렬 핀에 맞춥니다.. 가볍게 눌러 제자리에 고정하세요. 고정 나사를 십자 패턴으로 조여 균일한 압력을 보장합니다.. 서비스 설명서의 사양에 따른 토크 (일반적으로 0.3–0.4 N·m). 지나치게 조이지 마십시오, 접시가 깨질 수 있으므로.
테스트 및 교정
전원을 다시 연결하고 제어판에서 노즐 검사를 실행하세요.. 노즐이 여전히 누락된 경우, 부드러운 청소 주기를 수행하세요. 테스트 패턴을 인쇄하여 정렬 및 색상 균일성을 확인합니다.. 필요한 경우 양방향 오프셋을 조정합니다.. 출력이 품질 표준을 충족하면, the NC-UVDTF60 Nozzle plate replacement is complete and the printer is ready for production.
교체 후 관리
처음 몇 시간 동안 인쇄 품질을 면밀히 모니터링하십시오.. 이후 후속 노즐 점검 일정을 계획하십시오. 8 영업 시간. 와이퍼 블레이드가 마모된 경우 교체하십시오.. 교체 후 적절한 유지 관리로 장기적인 신뢰성 보장.
노카이 – 전문 UV 프린터 제조업체 | 디지털 인쇄 솔루션